The frequency to measured may be observed from four possible inputs:
Spock option register bits R7:2/1 are programmed to select the input:
Bit Name Value Meaning 2/1 Trig Bit 7 MUX 0 DD7 : Digital Data Bus Bit 7. 1 Comparator : trigger match comparator signal. 2 Event 1 : (Pre-scaler output frequency halved). 3 Event 2 : (ADC input frequency halved).
If the ADC input is selected the Input/Attenuation Register R14 also must be programmed to select the appropriate input and level attenuation for the primary trace channel.
The secondary trace channel is not used.